BAFFLES SILENCERS, SPLITTERS and DUCTS
Standard baffles with glass cloth
Standard baffles with expanded metal
Standard baffles with inner resonator
Acoustic galvanized grille
Double acoustic galvanized grille
Baffle silencer -10dB(A)
Baffle silencer -14dB(A)
Baffle silencer -19dB(A)
Baffle silencer -25dB(A)
Baffle silencer -30dB(A)
Baffle silencer -39dB(A)
Customized baffles
Customized ducts
ACOUSTIC ENCLOSURES
ABSOLUTE FILTRATION
Glass micro fiber E10
Flanged metallic frame E10
HEPA filter aluminium frame H13 to H14
HEPA filter MDF frame H13 to H14
Pleat filter E10 to H14
High flow E10 to H14
High temperature H13-H14
Multihedral high flow H13
Laminar flow H14
Laminar flow H14 gel seal
Flanged laminar flow H14
ULPA filter aluminium frame U15
ULPA filter MDF frame U15
AXIAL FANS
High flow, short housing type
High flow, long housing type
High pressure type
Heavy duty type for genset
High flow, high temperature, belt driven type
High flow, wall mounted type
Wall mounted type
To be built-in duct or wall
ATEX High flow, short housing type
ATEX High flow, long housing type
Exproof High pressure type
ATEX Wall mounted type
CENTRIFUGAL FANS
Low flow and low pressure, for clean air
Low flow and high pressure, for dusty air
Centrifugal box fan, galvanized steel
Fully dismantabled box fan
High flow, for clean air
High flow, for highly dusty air
High pressure, for laden air
For heavy dusty air with wood chips
ATEX Low flow and low pressure, for clean air
ATEX Low flow and high pressure, for dusty air
ATEX High flow, for clean air
ATEX High flow, for highly dusty air
ATEX High pressure, for laden air
- Air permeability class 2 for single leaf, class 3 for double leaf
- Thermal transmittance 1,57 W/m²K below 3,6m², 2,02 W/m²K up to 3,6m²
- Available in single leaf from 800 x 2050 to 1100 x 2150
- and in double leaf from 1200 x 2050 to 2000 x 2150
Budget price given for a single leaf model 800 x 2050 fully galvanized with epoxy paint on both sides without accessories
Fabrication
- Solid design and manufacture
- Fully galvanized door, including the “hidden” parts
- Corrosion protection also provided along cut edges of the metal sheets
- Painted with epoxy-polyester thermoset powders in a 180°C oven
- Substantial paint layer (70 microns plus)
- Optimal corrosion resistance demonstrated by 500 hour salt-fog test
- Unaffected by severe climate changes, demonstrated by 2000 hours with +60°C to -10°C cycles at 75% humidity
- Finishing with high-quality aesthetics
- Orange skin anti-scratch structured paint
- Customizable with wide selection of RAL colors
Standard Elements
- Door leaf
-- Made of hot-galvanized sheet metal, press folded and electro welded
-- Perimetral rebate on 4 sides
-- Heat-insulated with mineral wool
-- Internal stiffeners for overhead door closer and panic bar
-- Thickness of 50 mm
- Door frame
-- Made of hot-galvanized sheet metal
-- Grooves for rebate sealing
-- Suitable for anchors for mortar fixing or expansion screws
-- Detachable rebate for application on finished flooring
-- Removable threshold for threshold-less installation (except for external doors CE marked)
-- Strike plates in black plastic for lock bolt
-- Assembled door frames for one-leaved doors
-- Assembly required for two-leaved door frames
- Hinges
-- 3 hinges for each leaf
-- of which one 1 ball-bearing hinge with screws for vertical adjustment of the leaf, marked as per EN 1935, classified for up to 160 kg load, 200.000 cycles durability, suitable for fire door use
-- and one hinge with self-closing spring
-- 3 safety bolts applied on hinge side door frame edge
- Locking mechanism and Handle
-- Reversible locking mechanism with bolt and central latch
-- Insert with patent key, Euro profile cylinder ready
-- Black plastic handle
-- Fastener screws to pass
-- Insert for patent-type key
-- Safety lock with central latch for blocking and unblocking the inactive leaf
- Upper coupling system for the inactive leaf
-- Vertical rod with steel point which inserts into the upper strike box
-- Upper strike box in black plastic with steel roller
- Lower coupling system for the inactive leaf
-- Vertical rod with steel point which inserts into lower strike box
-- Floor catch (floor-mounted bushing) in black plastic, for doors without threshold
-- Floor catch in black plastic with steel roller, for doors with threshold
Conditions
- Wind resistance class C2
- Water resistance class 2A to 3A for double leaf model
- Thermal transmittance 1,57 W/m²°C to 2,02 w/m²°C
- Air permeability class 2 to class 3
- Suitable for use with panic bar
- Ambient temperature between -10°C to +60°C
- indoor & outdoor installation
Options
- Suitable for multiple uses because of its sturdiness
- Vast assortment of accessories
- Customized measurements also available
- Very wide field of application
- Air permeability class 2 for single leaf, class 3 for double leaf
- Thermal transmittance 1,57 W/m²K below 3,6m², 2,02 W/m²K up to 3,6m²
- Available in single leaf from 800 x 2050 to 1100 x 2150
- and in double leaf from 1200 x 2050 to 2000 x 2150
Budget price given for a single leaf model 800 x 2050 fully galvanized with epoxy paint on both sides without accessories