ATEX Axial roof extractor for explosive gas extraction
ATEX Axial turret designed to ensure the air extraction in hazardous area, for clean or little dusty air, for small & medium extraction flow
- Air flow from 450 m3/h to 8 500 m3/h
- Pressure from 13 Pa to 125 Pa
- ATEX IIB & IIC
Description
ATEX axial fan for air roof extraction in hazardous area
Designed to ensure small & medium air flow extraction of clean & little dusty air
Fabrication
- Housing galvanized carbon steel
- base plate galvanized carbon steel
- Cap galvanized carbon steel
- Grid at inlet and outlet
- Motor CE Ex II2 G T* IIB or CE Ex II2 G T* IIC, for area 1(Gb) or 2 (Gc) (for ATEX model)
CE Ex II2 D T* IIIB or CE Ex II2D T* IIIC, for area 21(Db) or 22 (Dc), 50Hz, 400V three phased Motor
- Propeller Composite antistatic or aluminum alloy
Conditions
- Ambient temperature between -20°C and +40°C (unless otherwise paid to the motor nameplate)
- Fluid temperature between -20°C and +40°C
- Roof installation
Standards
- In accordance with machine directive 2006/42/EC and Directive 2009/125/EC Ecodesign "ERP"
- Safety in accordance with EN ISO 12499
- Turbine balanced ISO 1940 (standard class G6.3)
Each turret tested in operation with vibration control according to ISO 14694
All performance values are given for 15°C, for other data please contact us
Product Details
Data sheet
- Material
- galvanized carbon steel
- Air quality
- Clean
- propeller
- compsite or aluminum